Page 16 The following table is a list of symbols and definitions that may be used with d= 1.2 x √P d= 1.2 x √P d= 2.3 x √P AirSep’s VisionAire Oxygen Concentrator. These symbols are referenced from the appropriate International Electro-technical Commission (IEC) standards: 0.01 0.12 0.12. MN138-1 Rev J Oxygen Concentrator Service Manual For VisionAire, VisionAire 2 & VisionAire 3 Models Page: 1 12 MN138-1 Rev J 4.3.2 Capacitor Replacement The capacitor starts the compressor.
*Visionair Concentrator Service Manual Instructions
*Visionair Concentrator Service Manual Pdf
*Manual Car Service Manuals
*Visionaire Oxygen Concentrator Service Manual
*Visionaire Concentrator Service Manual TroubleshootingOxygen concentrators and liquid oxygen systems (LOX).
Equipment of Respironics and Philips might be identical.
AirSep Centrox PSA Service manual
3.4 MB Download
AirSep LifeStyle Service manual
480 kB Download
AirSep NewLife Elite Service manual
1.3 MB Download
Visionair Concentrator Service Manual InstructionsAirsep Newlife Elite Service manual
11.1 MB Download
Airsep NewLife Intensity 10 Service manual
600 kB Download
AirSep QuietLife 5 Service manual
460 KB Download
Airsep VisionAire Service manual
3.2 MB Download
Culligan Spare part list
830 KB Download
DeVilbiss Maintenance log
1.3 MB Download
DeVilbiss 303, 501, 505 Service manual
2.3 MB Download
DeVilbiss 515 Service manual
2.4 MB Download
DeVilbiss 515A Service manual
1.2 MB Download
DeVilbiss 525 Service manual
2.3 MB Download
DeVilbiss 535D Service manual
1.7 MB Download
DeVilbiss MC44 Service manual
2.0 MB Download
DeVilbiss SolAiris III Service manual
2.3 MB Download
DeVilbiss Maintenance log
180 KB Download
Invacare 3-6 Service manual
1.1 MB Download
Invacare Perfecto 2, Platinum 5 Spare part list
4.2 MB Download
Invacaire Platinum 5 Service manual
1.7 MB Download
Invacare Platinum 5 Spare part list
1.6 MB Download
Invacare Platinum 5 + 10 Service manual
3.8 MB Download
Inogen One G2 Service and user manual
80 kB Download
Kröber O2 Technical information
4.1 MB Download
Lonfian Scitech Jay Service manual
600 kB Download
Lonfian Scitech Jay Service manual
1.2 MB Download
Lonfian Scitech Jay User and service manual
2.9 MB Download
Lonfian Scitech Jay User and service manual
700 kB Download
Longfian Jay - Changing Filters Service manual
1.3 MB Download
Nidek Mark 5 Nuvo Service manual
1.2 MB Download
Nidek Mark 5 Nuvo Service manual
1.1 MB Download
Nidek Mark 5 Nuvo Lite Service manual (2010)
1.0 MB Download
Nidek Mark 5 Nuvo Lite Service manual (2011)
1.8 MB Download
Nidek Mark 5 Nuvo Lite Service manual (2013)
1.0 MB Download
Visionair Concentrator Service Manual PdfNidek Mark 5 Nuvo Lite Service manual (2018)
1.2 MB Download
Nidek Mark 5 Plus Service manual
450 KB Download
Nidek Mark 5 Nuvo Lite Service manual (2018)
1.2 MB Download
Nidek Nuvo 5, 8, 10 Service manual (2018)
3.6 MB Download
Nidek Nuvo 8 Service manual
1.5 MB Download
Nidek Max 30 Service manual (2017)
1.5 MB Download
Nidek Max 30 Service manual (2017)
Manual Car Service Manuals 1.0 MB Download
Philips EverFlo Service manual
7.2 MB Download
Precision EasyFlow 5 Service manualVisionaire Oxygen Concentrator Service Manual
2.1 MB Download
Puritan Bennett Companion 492, 590 Service manual
10.2 MB Download
Puritan Bennett Companion Mobile Liquid Oxygen System Test proceduresVisionaire Concentrator Service Manual Troubleshooting
950 KB Download
Respironics Millennium Service manual
7.8 MB Download
Weinmann Oxymat 3 Service manual
4.7 MB Download
Rietschle Thomas 2638xxxx190 Compressor (for serval concentrators) Service manual
1.0 MB Download
Thomas 2638xxxx190 Compressor (for several concentrators) Service manual
470 KB Download
Sequal Integra Service manual
430 KB Download
VisionAire 2, 3 Service manual
2.6 MB Download
AirSep visionaire: Transcript
*
26 MN138-1 Rev J 5.0 Troubleshooting 5.1 Operating Pressure Test Testing the operating pressure is a useful diagnostic tool when a concentrator has low oxygen concentration and requires servicing. Units functioning normally do not require operating tests. Use the following procedure to test the operating pressure of the unit: ...
*
iii MN138-1 Rev J Table of Contents Section 1.0 Introduction 1.1 Equipment Provider Responsibility 1 1.2 Important Notice and Symbol Explanations 2 1.3 Functional Specifications 5 Section ...Page: 3
*
1 MN138-1 Rev J 1.0 Introduction 1.1 Equipment Provider Responsibility All Equipment Providers of the VisionAireâ„¢ Oxygen Concentrator must assume responsibilities for handling, operational check-out, patient instruction, and oxygen concentration checks. These responsibilities are outlined below and throughout this manual. ...
*
3 MN138-1 Rev J Symbol Description Symbol Description Consult the accompanying documents Keep unit and accessories dry Use no oil or grease Proper disposal of waste of electrical and electronic equipment required Oxygen outlet connection to the cannula Do ...Page: 8
*
v MN138-1 Rev J Section 5.0 Troubleshooting 5.1 Operation Pressure Test 26 5.1.1 High Operating Pressure 26 5.1.2 Low Operating Pressure 26 5.2 General Troubleshooting 27 ...
*
23 MN138-1 Rev J 4.14 Oxygen Monitor Circuit Board Replacement (In Equipped Units) Oxygen Monitor Circuit Board Removal To remove the circuit board, follow the steps below: Care must be taken when removing and installing tubing to circuit board sensor to prevent damaging sensor. 1. Set the unit’s I/0 switch to the “0†...Page: 28
*
15 MN138-1 Rev J Leaks can be so small in air loss that oxygen concentration is not affected immediately. The sieve material can become contaminated gradually. Careful leak testing is important as the sieve material can become contaminated gradually with very small leaks. If replacement is necessary, you must replace bot ...
*
6 MN138-1 Rev J 2.0 Operational Check and Oxygen Concentration Test 2.1 Description of Operation Air is drawn into the VisionAire Oxygen Concentrator. For overall, sound efficiency, before air enters the compressor, it passes through the unit’s intake muffler. Pressurized air then exits the compressor and moves to the valve man ...Page: 11
*
4 MN138-1 Rev J Classification Type of protection against electric shock: Class II Protection from electric shock is achieved by DOUBLE INSULATION. Protective earthing or reliance upon installation conditions is not required. Degree of protection against electric shock: Type BF Equipment providing a particul ...
*
19 MN138-1 Rev J When the lockout adjustment is no longer required, follow the normal regulator setting procedure as described in Section 4.8.1. 4.8.3 Back Pressure Correction at Maximum Flow Rate In some cases, additional lengths of oxygen tubing with a humidifier bottle can increase back pressure and limit oxygen flow below the ...Page: 24
*
29 MN138-1 Rev J Problem Probable Cause Solution Compressor relief valve activates (popping sound) ï‚· Faulty electrical connection at waste valve. ï‚· Faulty solenoid valve coil. ï‚· (Acceptable rating: 713-837 Ohms) ï‚· Contaminated sieve beds. ï‚· Faulty circuit board. ï‚· Faulty relief valve. ...
*
MN138-1 Rev J CAIRE Inc. 2200 Airport Industrial Dr., Ste 500 Ball Ground, GA 30107 www.chartindustries.com/RespiratoryHealthcare CAIRE reserves the right to discontinue its products, or change the prices, materials, equipment, quality, description ...Page: 37
*
30 MN138-1 Rev J Problem Probable Cause Solution Low oxygen concentration.  Ambient or unit’s temperature is too high.  Leak.  Reduced air intake (suction)  Restriction in exhaust muffler  Contaminated sieve beds  Weak compressor.  Faulty circuit boar ...